Chain-Link NVM Name
742-151
Loop Amount Adjustment
(MSI/126[mm/s]/Heavyweight)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-152
Loop Amount Adjustment
(MSI/63[mm/s]/Heavyweight)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-153
Loop Amount Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-154
Loop Amount Adjustment
(MSI/126[mm/s]/Labels)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-155
Loop Amount Adjustment
(MSI/63[mm/s]/Labels)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-156
Loop Amount Adjustment
(MSI/63[mm/s]/HW Labels)
("Regi Snr On detection"~"MSI Feed
CL Stop")
742-157
Loop Amount Adjustment
(Duplex/126[mm/s]/Plain);
("Regi Snr On Detection"~"Dup CL
Stop")
742-158
Loop Amount Adjustment
(Duplex/126[mm/s]/Heavyweight);
("Regi Snr On Detection"~"Dup CL
Stop")
742-159
Loop Amount Adjustment
(Duplex/63[mm/s]/Heavyweight);
("Regi Snr On Detection"~"Dup CL
Stop")
Version 1.1
DC SC2020
Table 1 NVM 742_Paper Handling List
Default
Minimum
Maximum
Value
value
value
Description
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (MSI/126[mm/s]/Heavy-
weight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 157.
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (Tray1/63[mm/s]/Heavy-
weight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 314.
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (Tray1/63[mm/s]/Heavy-
weight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 314.
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (MSI/126[mm/s]/Labels)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 157.
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (MSI/63[mm/s]/Labels)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 314.
0
-125
125
Adjusts the timing of when the MSI Feed CL should stop after the Regi Snr ON (MSI/63[mm/s]/Labels2)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
+/-125ms Adjustment possible as 0 = 157.
-16
-125
125
Adjusts the timing of when the Duplex CL should stop after the Regi Snr ON (Duplex/126[mm/s]/Plain)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the Duplex Clutch OFF timing.
+/-125ms Adjustment possible as 0 = 157.
-48
-125
125
Adjusts the timing of when the Duplex CL should stop after the Regi Snr ON (Duplex/126[mm/s]/Heavy-
weight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the Duplex Clutch OFF timing.
+/-125ms Adjustment possible as 0 = 157.
-96
-125
125
Adjusts the timing of when the Duplex CL should stop after the Regi Snr ON (Duplex/63[mm/s]/Heavy-
weight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the Duplex Clutch OFF timing.
+/-125ms Adjustment possible as 0 = 314.
05/2014
6-47
Write
Allowed/
Can be
Protected
initialized
O
X
O
X
O
X
O
X
O
X
O
X
O
O
O
O
O
O