Fuji Xerox DocuCentre SC2020 Service Manual page 550

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
Chain-Link NVM Name
755-095
PV for creating ADC_Mid/End[K]
755-096
PV for creating ADC_TC[YMC]
755-097
PV for creating ADC_TC[K]
755-098
ICDC Integrated Value for ADC [Y]
755-099
ICDC Integrated Value for ADC [M]
755-100
ICDC Integrated Value for ADC [C]
755-101
ICDC Integrated Value for ADC [K]
755-102
ICDC Integrated Value for ADC_TC[Y]
755-103
ICDC Integrated Value for ADC_TC[M]
755-104
ICDC Integrated Value for ADC_TC[C]
755-105
ICDC Integrated Value for ADC_TC[K]
755-106
ICDC Move Mean Integrated Value [Minor-
ity][Y]
755-107
ICDC Move Mean Integrated Value [Minor-
ity][M]
755-108
ICDC Move Mean Integrated Value [Minor-
ity][C]
755-109
ICDC Move Mean Integrated Value [Minor-
ity][K]
755-110
ICDC Move Mean Integrated Value [Major][Y]
755-111
ICDC Move Mean Integrated Value [Major][M] 0
755-112
ICDC Move Mean Integrated Value [Major][C]
755-113
ICDC Move Mean Integrated Value [Major][K]
755-114
Delta Temperature
755-115
Delta Temperature_Setup[BW]
755-116
Delta Temperature_Setup[FC]
755-117
Delta Humidity
755-118
Delta Humidity_Setup[BW]
755-119
Delta Humidity_Setup[FC]
755-120
Delta Absolute Humidity
755-121
Delta Humidity_Setup Performing Requirement 0
755-122
Delta Humidity_Target Value
755-123
Delta Humidity_Disp
755-124
Delta Humidity_Potential
755-125
Delta Humidity_Device
05/2014
6-152
Table 1 NVM 755_Process Control 4 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
65535
PV for determining Mid/EndSetup Patch creation
0
0
65535
PV for determining TCSetup Patch creation
0
0
65535
PV for determining TCSetup Patch creation
0
0
10000000
ICDC Count Integrated Value between ADC_Mini/Mid/End Patch
0
0
10000000
ICDC Count Integrated Value between ADC_Mini/Mid/End Patch
0
0
10000000
ICDC Count Integrated Value between ADC_Mini/Mid/End Patch
0
0
10000000
ICDC Count Integrated Value between ADC_Mini/Mid/End Patch
0
0
10000000
ICDC Count Integrated Value between ADC_TC Patch
0
0
10000000
ICDC Count Integrated Value between ADC_TC Patch
0
0
10000000
ICDC Count Integrated Value between ADC_TC Patch
0
0
10000000
ICDC Count Integrated Value between ADC_TC Patch
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
0
67042305
The ICDC moving average integrated value obtained using an algorithm
similar to moving average
0
-128
127
Delta Temperature
0
-128
127
Delta Temperature during Setup
0
-128
127
Delta Temperature during Setup
0
-128
127
Delta Humidity
0
-128
127
Delta Humidity during Setup
0
-128
127
Delta Humidity during Setup
0
-1024
1023
Delta Absolute Humidity (times 10 value)
-128
127
Delta Humidity_Setup Performing Requirement
0
-128
127
Delta Humidity_Target Value
0
-128
127
Delta Humidity_Disp
0
-128
127
Delta Humidity_Potential
0
-128
127
Delta Humidity_Device
General
6.3.15 NVM 755_Process Control 4 List
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents