11. Remove the sleeve at the rear. (Figure 9)
(1) Remove the Tapping Screw (x2).
(2) Remove the Sleeve.
Figure 9 j0bs40804
12. Replace with Drum in the Replacement Kit. (Figure 10)
(1) Replace the Drum.
Version 1.1
DC SC2020
NOTE: Be careful not to touch the old Drum because there is
grease on the both sides of the axis.
NOTE: Be careful not to touch the new Drum surface (Green
sensitized layer part).
Figure 10 j0bs40805
Replacement
1.
Return the Sleeve (Front/Rear) to the original state.
2.
Return the BCR Housing to the original state.
3.
Return the Xero Unit to the original state.
4.
Return the Waste Bottle to the original state.
5.
Close the Front Cover.
05/2014
4-41

REP 8.3.2 Drum Blade

Parts List on
PL 8.3
Removal
WARNING
When turning OFF the power switch, check that the "Data"
lamp is OFF and that there is no Job in progress.Turn OFF the
Power Switch and make sure that the screen display or energy-
saving LED is turned off.Check that the power switch is OFF
and unplug the power plug.
CAUTION
To prevent light fatigue, either wrap the removed Drum by using a
sheet of black paper or store it in a black bag.
NOTE: Place the drop cloth or newspapers at the servicing area to
keep the site clean.
1.
Prepare a sheet of black paper or a black bag.
2.
Open the Front Cover.
3.
Remove the Waste Bottle. (Figure 1)
(1) Turn the Retract Handle in counterclockwise direction.
(2) Release the hook (x2).
(3) RRemove the Waste Bottle.
Figure 1 j0bs40813
4.
Turn the replacement target color Lever (R1-R4) towards the
direction of the arrow.
5.
Remove Y, M, C, K of the Xero Unit. (Figure 2)
(1) Remove the screw (long).
Disassembly/Assembly and Adjustment