Fuji Xerox DocuCentre SC2020 Service Manual page 454

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
Chain-Link NVM Name
744-019
Fusing Motor Speed Fine Adjustment
(63[mm/s]/Heavyweight2,Labels2,Envelope)
744-020
Fusing Motor Speed Fine Adjustment
(63[mm/s]/HW Gloss)
744-021
Fusing Failure Individual Support Mode Shift Tem-
perature Plain 1
744-022
Fusing Failure Individual Support Mode Shift Tem-
perature Plain 2
744-023
Fusing Failure Individual Support Mode Shift Tem-
perature - Heavyweight
744-024
Fusing Failure Individual Support Mode Shift Tem-
perature - Extra Heavyweight
744-025
Toner Blocking Countermeasure Applied Paper
Type (Plain)
744-026
Toner Blocking Countermeasure Applied Paper
Type (Heavyweight BW)
744-027
Toner Blocking Countermeasure Applied Paper
Type (Heavyweight FC)
744-028
Toner Blocking Countermeasure Applied Paper
Type (Extra Heavyweight)
744-029
Toner Blocking Countermeasure Interval Adjust-
ment Value
(126mm/s)
744-030
Toner Blocking Countermeasure Interval Adjust-
ment Value
(63mm/s)
744-031
HFSI Warning Threshold Value
05/2014
6-56
Table 1 NVM 744_Fusing Unit List
Default
Minimum
Maximu
Value
value
m value
Description
-465
-600
600
NVM for Fusing Motor Speed Fine Adjustment. Adjust by setting the division ratio.
(63[mm/s]/Extra Heavyweight) (-0.2%)
-465
-600
600
NVM for Fusing Motor Speed Fine Adjustment. Adjust by setting the division ratio.
(63[mm/s]/HW Gloss) (-0.2%)
5
0
20
The shift temperature for run temperature
1 count = 1 [Degree]
5
0
20
The shift temperature for run temperature
1 count = 1 [Degree]
5
0
20
The shift temperature for run temperature
1 count = 1 [Degree]
5
0
20
The shift temperature for run temperature
1 count = 1 [Degree]
0
0
255
Specify the combined bits for the paper types to apply the countermeasure.
0: Do not apply, 1: PlainA, 2: PlainB, 4: PlainC, 8: PlainD, 16: PlainE, 32: PlainF,
64: PlainG, 128: Plain S
0
0
63
Specify the combined bits for the paper types to apply the countermeasure.
0: Do not apply, 1: Heavyweight1A (BW), 2: Heavyweight1B (BW), 4: Heavyweight
C (BW)
8: Heavyweight1S (BW), 16: Gloss1 (BW), 32: Labels (BW)
0
0
63
Specify the combined bits for the paper types to apply the countermeasure.
0: Do not apply, 1: Heavyweight1A (FC), 2: Heavyweight1B (FC), 4: Heavyweight
C (FC)
8: Heavyweight1S (FC), 16: Gloss1 (FC), 32: Labels (FC)
0
0
127
Specify the combined bits for the paper types to apply the countermeasure.
0: Do not apply, 1: Heavyweight2A (Include envelopes), 2: Extra Heavyweight B, 4:
Extra Heavyweight C,
8: Extra Heavyweight D, 16: Extra Heavyweight S, 32: HW Gloss, 64: Heavyweight
Labels
0
0
50000
Interval adjustment value
1count=1[ms]
0
0
100000
Interval adjustment value
1count=1[ms]
400000 0
1200000
Notifies the time for Fusing Unit replacement
Warning Value = HFSI Threshold Value - HFSI Warning Threshold Value
General
6.3.7 NVM 744_Fusing Unit List
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
1
O
O
[degree]
1
O
O
[degree]
1
O
O
[degree]
1
O
O
[degree]
-
O
O
-
O
O
-
O
O
-
O
O
1 [ms]
O
O
1 [ms]
O
O
-
O
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents