Figure 14 j0bs40512
Replacement
1.
Install the Deve Front Cover. (Figure 15)
Figure 15 j0bs40513
2.
The Deve Front Cover Spring should touch the Upper Cover.
(Figure 16)
Version 1.1
DC SC2020
Figure 16 j0bs40514
3.
Remove the paper and tape that closed the Pipe opening of the
Deve Rear Cover.
4.
Install the Deve Unit. (Figure 17)
Align the Deve Unit Rib to the Main Unit Guide.
Figure 17 j0bs40502
5.
Return the Xero Unit to the original state.
6.
Return the Waste Bottle to the original state.
7.
Close the Front Cover.
8.
It initializes the Life counter of Deve with the color which
entered CE mode behind the installation and was exchanged.
It implements Initialize in Printer Diag > Parameter > Life >
Deve HSG PV and it initializes the Life Counter.
05/2014
4-25
NOTE: The Life Counter initialization must be performed. If the
Life Counter is not initialized, it may result in poor image quality
and even a malfunction of the machine.
9.
It implements REGICON, forcing.
Tools > Admin > setting > Maintenance > Auto Registration
10. It implements PROCON, forcing.
Tools > Admin > setting > Maintenance > Quic density Adjust-
ment