Chain-Link NVM Name
752-185
Screen PV[Print Multi-Value][YMC]
752-186
Screen PV[Print Multi-Value][K]
752-187
Previous Panel Speed [YMC]
752-188
Previous Panel Speed [K]
752-189
Last Setup Speed [YMC]
752-190
Last Setup Speed [K]
752-191
EndSetup_ADC_Vcln Create Time Interval
752-192
ICDC Moving Average Value Minority][Y]
752-193
ICDC Moving Average Value [Minority] [M]
752-194
ICDC Moving Average Value [Minority] [C]
752-195
ICDC Moving Average Value [Minority] [K]
752-196
ICDC Moving Average Value [Majority] [Y]
752-197
ICDC Moving Average Value [Majority] [M]
752-198
ICDC Moving Average Value [Majority] [C]
752-199
ICDC Moving Average Value [Majority] [K]
752-202
Delta Deve Rotation No. of Sheet[Y]
752-203
Delta Deve Rotation No. of Sheet[M]
752-204
Delta Deve Rotation No. of Sheet[C]
752-205
Delta Deve Rotation No. of Sheet[K]
752-206
Delta PR Film Decrease Amount[Y]
752-207
Delta PR Film Decrease Amount[M]
752-208
Delta PR Film Decrease Amount[C]
752-209
Delta PR Film Decrease Amount[K]
752-210
After Temperature_Fail Determination
752-211
After Humidity_Fail Determination
752-212
Absolute Humidity
752-213
Maximum Temperature
752-214
Maximum Humidity
752-215
RADC_Potential_Reference Target Value[Y]
752-216
RADC_Potential_Reference Target Value[M]
Version 1.1
DC SC2020
Table 1 NVM 752_Process Control 1 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
4294967295 Screen Individual PV count
0
0
4294967295 Screen Individual PV count
0
0
1
Process Speed of Last Panel (0: 63mm/s, 1: 126mm/s)
0
0
1
Process Speed of Last Panel (0: 63mm/s, 1: 126mm/s)
0
0
1
Process Speed of Last Setup (0: 63mm/s, 1: 126mm/s)
0
0
1
Process Speed of Last Setup (0: 63mm/s, 1: 126mm/s)
60
0
65535
EndSetup_ADC_Vcln Create Time Interval
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
The ICDC moving average value obtained using an algorithm similar
to moving average
0
0
65535
Developing Machine Rotation No. of Sheet from Initial Developer
0
0
65535
Developing Machine Rotation No. of Sheet from Initial Developer
0
0
65535
Developing Machine Rotation No. of Sheet from Initial Developer
0
0
65535
Developing Machine Rotation No. of Sheet from Initial Developer
0
0
1023
Photoreceptor Film Decrease Amount from Photoreceptor Initial Film 0.1[m]
0
0
1023
Photoreceptor Film Decrease Amount from Photoreceptor Initial Film 0.1[m]
0
0
1023
Photoreceptor Film Decrease Amount from Photoreceptor Initial Film 0.1[m]
0
0
1023
Photoreceptor Film Decrease Amount from Photoreceptor Initial Film 0.1[m]
0
-128
127
Temperature after Sensor Fail Determination (times1 value)
0
0
127
Humidity after Sensor Fail Determination (times 1 value)
0
0
1023
Absolute Humidity (10times the value of Capacity Absolute Humidity
g/m3)
0
-1024
1023
Maximum Temperature (times10 value)
0
0
2047
Maximum Humidity (times10 value)
365
0
1023
RADC Reference Target Value for Potential Control
365
0
1023
RADC Reference Target Value for Potential Control
05/2014
6-103
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
minute
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
100 [PV]
O
O
100 [PV]
O
O
100 [PV]
O
O
100 [PV]
O
O
O
O
O
O
O
O
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
6.3.13 NVM 752_Process Control 1 List
General

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents