Fuji Xerox DocuCentre SC2020 Service Manual page 612

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
6.
The current value of the Heat Roll STS is displayed in hexadecimal (16).
Figure 2 j0bs640149
7.
Press the [<--] (Back) button to return to the [Printer Diag] screen.
Figure 3 j0bs64016
8.
Exit the CE mode. (See "6.4.4 How to Exit the CE Mode".)
05/2014
6-214
6.4.8.4 NVM Setting
NVM (EEPROM of IOT) can access control panel key operation.
Reserve the following features.
Able to read/write the contents from/to the IOT NVM.
NOTE: NVM List of IOT can be found in 6.3.3 - 6.3.21.
6.4.8.4.1 Read/Write from/to NVM (Edit NVM)
Read/Write the contents from/to the IOT NVM.
"Read/Write NVM (Edit NVM)" is to change the device-specific settings and the inadvertent operation or
missing settings may be an unrecoverable failure.
Operation Procedure
1.
Enter the CE Mode. (Refer to
"6.4.2
2.
Make sure [Printer Diag] is selected, and then press [OK] button.
3.
[Down arrow] "IOT Diag" button to select, and then press [OK] button.
4.
[Down arrow] "NVM Settings" button to select, and then press [OK] button.
6.4.8.4 NVM Setting
CAUTION
How to Enter the CE Mode")
Figure 1 j0bs64010
General