5 DATA USED FOR POSITIONING CONTROL
Item
Da.6
Positioning address/
movement amount
Da.4 Deceleration time No.
Set which of "deceleration time 0 to 3" to use for the deceleration time during
positioning.
0 : Use the value set in "
1 : Use the value set in "
2 : Use the value set in "
3 : Use the value set in "
Da.5 Axis to be interpolated
Set the target axis (partner axis) for operations under the 2-axis interpolation
control.
0 : Selects the axis 1 as the target axis (partner axis).
1 : Selects the axis 2 as the target axis (partner axis).
2 : Selects the axis 3 as the target axis (partner axis).
3 : Selects the axis 4 as the target axis (partner axis).
•
Note)
Do not specify the own axis number or any number except the above.
(If you do, the "Illegal interpolation description command error" will
occur during the program execution (error code: 521).)
•
This item does not need to be set in case 3 or 4-axis interpolation is
selected.
Setting value, setting range
Value set with peripheral device
The setting value range differs according to the "
system".
Here, the value within the following range of [Table 1] range is set.
Da.6 Positioning address/movement amount
Set the address to be used as the target value for positioning control.
The setting value range differs according to the "
((1) to (4))
(1) Absolute (ABS) system, current value changing
•
The setting value (positioning address) for the ABS system and current value
changing is set with an absolute address (address from OP).
-1000
Movement
amount
Pr.10
Deceleration time 0".
Pr.28
Deceleration time 1".
Pr.29
Deceleration time 2".
Pr.30
Deceleration time 3".
Value set with PLC program
Da.2
[Table 1] on right page
1000
Movement
: 2000
amount
5 - 94
Setting value buffer memory
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Control
2006
0
2007
Da.2
Control system".
Stop position
(positioning start address)
3000
: 2000
MELSEC-Q
address
8006
14006
20006
8007
14007
20007