Mitsubishi Electric MELSEC-QD75MH1 User Manual page 425

Positioning module
Table of Contents

Advertisement

9 MAJOR POSITIONING CONTROL
[2] 4-axis linear interpolation control (INC linear 4)
Operation chart
In the incremental system 4-axis linear interpolation control, using an address
established by a machine OPR in the 4-axis coordinate plane, a linear interpolation
positioning is carried out from the current stop position (start point address) to a
position at the end of the movement amount set in the "
address/movement amount". The movement direction depends on the sign (+ or -)
of the movement amount.
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.
When the movement amount for each axis exceeds "1073741824 (=2
An "outside linear movement amount range error (error code: 504)" will occur at
the positioning start.
(The maximum movement amount that can be set in "
address/movement amount" is "1073741824 (=2
9 - 42
MELSEC-Q
Da.6
Positioning
30
Da.6
Positioning
30
)".)
)"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q seriesMelsec-qd75mh2Melsec-qd75mh4

Table of Contents