9 MAJOR POSITIONING CONTROL
Restrictions
(1) An axis error "Continuous path control not possible (error code: 516)" will
occur and the operation cannot start if "continuous path control" is set in
"
Da.1
Operation pattern". ("Continuous path control" cannot be set in fixed-
feed control.)
(2) "Fixed-feed" cannot be set in "
when "continuous path control" has been set in "
the immediately prior positioning data. (For example, if the operation pattern of
positioning data No. 1 is "continuous path control", fixed-feed control cannot
be set in positioning data No. 2.) An axis error "Continuous path control not
possible (error code: 516)" will occur and the machine will carry out a
deceleration stop if this type of setting is carried out.
Positioning data setting example
[Reference axis is designated as axis 1.]
The following table shows setting examples when "3-axis fixed-feed control (fixed-
feed 3)" is set in positioning data No. 1 of axis 1. (The required values are also set
in positioning data No. 1 of axis 2 and axis 3.)
Da.2
Control system" in the positioning data
9 - 50
MELSEC-Q
Da.1
Operation pattern" of