5 DATA USED FOR POSITIONING CONTROL
Setting Value, setting range
Value set with peripheral device
Servo amplifier setting invalid
(
: Valid,
: Invalid)
MR-J3-B
2: The PC
corresponds with servo parameter No. of the servo amplifier.
3: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75MH), then switch it
on again to make that parameter setting valid.
Value set with PLC program
1 to 200
0 to 1000
0
H
Encoder output pulse
phases selection
Encoder output pulse setting
selection
1:
is used to set up the setting
value. (Hexadecimal)
0
0
H
Encoder cable
communication
system selection
1:
is used to set up the setting
value. (Hexadecimal)
0 to 1
0 to 10000
0 to D
5 - 81
MELSEC-Q
Setting value buffer memory
address
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
3
30164 30364 30564 30764
0
30165 30365 30565 30765
0000
30166 30366 30566 30766
H
0000
30167 30367 30567 30767
H
0
30168 30368 30568 30768
50
30170 30370 30570 30770
0
30172 30372 30572 30772
H