Structure of modules on CC-Link IE TSN and Ethernet devices

Connection with modules on CC-Link IE TSN and Ethernet devices
■Line topology
The network with modules and devices is configured in a line topology. A general-purpose switching hub is not required.
Up to eight CC-Link IE TSN Class B devices can be connected to the master station at the position indicated with (1).
Connect Ethernet devices to the end of the network.
No.0
Class B
No.0: Master station
No.1: Remote station (1st station)
No.8: Remote station (8th station)
No.9: Remote station (9th station)
(2) Ethernet device
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
When an error occurs in a device station, the stations connected after the faulty station will be disconnected.
■Star topology
Modules or devices are connected in a star topology via a general-purpose switching hub.
General-purpose
No.0
switching hub
Class B
or
TSN switching hub
No.1
Class A
A
No.0: Master station
No.1, No.2: Remote station
(1) Ethernet device (such as a personal computer)
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
4.4 Structure of CC-Link IE TSN Class B/A Devices (CC-Link IE TSN Protocol version 1.0 Only) and Ethernet Devices
(1)
No.1
Class B
No.2
Class A
(1)
No.8
No.9
Class B
Class A
4 SYSTEM CONFIGURATION