3.4

Ethernet Connection

This function connects an Ethernet device to a module without interfering with CC-Link IE TSN.

Connection with MELSOFT products

Programming and monitoring of the programmable controller are performed via Ethernet using the engineering tool. This
function enables remote control using long-distance connectivity and high-speed communications via Ethernet.
The following table lists the methods of connecting the Motion module to MELSOFT products (such as engineering tool).
: Connection available, : Connection not available
Connection method
Connection via a HUB
(Connection by specifying the IP address)
Connection via a HUB
(Connection by specifying the network number
and station number)
A station with a communication speed different from the communication speed of the station to which the
engineering tool is connected cannot be connected by specifying another station. The online and debug
function of the engineering tool may not be used.
Connection via a HUB
■Settings on the Motion module side
• For connection by specifying the IP address, set the IP address using "Required Settings". (Page 99 Station No./IP
Address Setting)
• For connection by specifying the network number and station number, set the network number and station number in
"Required Settings".
Neither of connections require "Network Configuration Settings" under "Basic Settings".
Purpose
To connect multiple MELSOFT products
To connect multiple MELSOFT products
Availability
Reference
MELSOFT
product
Page 39 Connection
via a HUB
3 FUNCTIONS
3.4 Ethernet Connection
3
39