Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 183

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Protocol information
■Protocol operation status (Un\G91270)
The operation status of the protocol is stored.
• 0: Operation protocol is undetermined, or "CC-Link IE TSN Class Setting" is set to "CC-Link IE TSN Class B Only".
• 1: A device is operating with the CC-Link IE TSN Protocol version 1.0.
• 2: A device is operating with the CC-Link IE TSN Protocol version 2.0.
Timeslot information for device station cyclic transmission
■Timeslot information for device station cyclic transmission (Un\G91286 to Un\G91309)
The timeslot for cyclic transmission is stored for each station number.
Address
Un\G91286
Un\G91309
Information for ensuring cyclic data are sent/received
■Multiple period setting (low speed) (Un\G91312)
The setting value of the multiple period setting (low speed) for ensuring that cyclic data are sent/received is stored.
• 0: Not calculated
• 16, 32, 64, 128: The "low speed" period for the basic period
(Conditions where a value is stored)
A value is stored in the buffer memory if the following conditions are met.
"CC-Link IE TSN Class Setting" of "Network Configuration Settings" is set to "CC-Link IE TSN Class A" and "Communication
Period Setting" is set to "Low-Speed" for any of the device stations.
However, no value is stored in the buffer memory if the following condition is met.
In "Network Configuration Settings", "General CC-Link IE TSN Module" is set for all
■Communication cycle interval (calculation value) (Un\G91313)
The setting value of the communication period interval for ensuring that cyclic data are sent/received is stored.
• 0: Not calculated
• 125 to 4294967295: Communication cycle interval (unit: s)
(Conditions where a value is stored)
A value is stored in the buffer memory if the following conditions are met.
"CC-Link IE TSN Class Setting" of "Network Configuration Settings" is set to "CC-Link IE TSN Class A" and "Communication
Period Setting" is set to "Low-Speed" for any of the device stations.
However, no value is stored in the buffer memory if the following condition is met.
In "Network Configuration Settings", "General CC-Link IE TSN Module" is set for all
Description
The timeslot for cyclic transmission (Station No.1) is stored.
• 0: Undetermined
• 1: Timeslot 1
• 3: Timeslot 3
• 4: Timeslot 4
• 5: Timeslot 5
• 6: Timeslot 6
The timeslot for cyclic transmission (Station No.24) is stored.
• 0: Undetermined
• 1: Timeslot 1
• 3: Timeslot 3
• 4: Timeslot 4
• 5: Timeslot 5
• 6: Timeslot 6
APPX
Appendix 1 Buffer Memory
A