Structure With Modules On Cc-Link Ie Tsn And Ethernet Devices - Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Structure with modules on CC-Link IE TSN and Ethernet devices

Connection with modules on CC-Link IE TSN and Ethernet devices
■Line topology
The network with modules and devices is configured in a line topology. A TSN switching hub is not required.
Connect Ethernet devices to the end of the network.
No.0
No.0: Master station
No.1 and No.2: Remote station
(1) Ethernet device (such as a personal computer)
When an error occurs in a device station, the stations connected after the faulty station will be disconnected.
■Star topology
The network is configured in a star topology via a switching hub.
Device stations cannot be connected with a general-purpose switching hub. Line and star topologies should be mixed in the
same network configuration.
No.0
No.1
No.0: Master station
No.1: Remote station
(1), (2): Ethernet device
4 SYSTEM CONFIGURATION
60
4.1 Structure of CC-Link IE TSN Class B devices and Ethernet devices
No.1
(1)
TSN switching
hub
(2)
(1)
No.2
No.0
No.1
(1)
General-purpose
switching
hub
(2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-40ssc-gMelsec iq-f fx5-80ssc-g

Table of Contents