Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 178

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Device area
The RX, RY, RWw, RWr, SB, and SW values are stored.
■Remote input (RX) (Un\G63140 to Un\G64163)
The RX value is stored. The RX start number and number of points for each station number can be checked by the RX offset/
size information (Un\G68900 to Un\G69423). (Page 177 RX offset/size information)
Address
b15
Un\G63140
RX
F
Un\G64163
RX
3FFF
Each bit corresponds to 1 bit of RX.
■Remote output (RY) (Un\G64164 to Un\G65187)
The RY value is stored. The RY start number and number of points for each station number can be checked by the RY offset/
size information (Un\G69424 to Un\G69947). (Page 178 RY offset/size information)
Address
b15
Un\G64164
RY
F
Un\G65187
RY
3FFF
Each bit corresponds to 1 bit of RY.
■Remote register (RWw) (Un\G65188 to Un\G66211)
The RWw value is stored. The RWw start number and number of points for each station number can be checked by the RWw
offset/size information (Un\G69948 to Un\G70471). (Page 178 RWw offset/size information)
Address
b15
Un\G65188
RWw0
Un\G65189
RWw1
Un\G66211
RWw3FF
■Remote register (RWr) (Un\G66212 to Un\G67235)
The RWr value is stored. The RWr start number and number of points for each station number can be checked by the RWr
offset/size information (Un\G70472 to Un\G70995). (Page 178 RWr offset/size information)
Address
b15
Un\G66212
RWr0
Un\G66213
RWr1
Un\G67235
RWr3FF
■Link special relay (SB) (Un\G67236 to Un\G67491)
The SB value is stored.
Address
b15
Un\G67236
SBF
Un\G67491
SBFF
F
Each bit corresponds to 1 bit of SB.
APPX
176
Appendix 1 Buffer Memory
b14
b13
b12
b11
RX
RX
RX
RX
E
D
C
B
RX
RX
RX
RX
3FFE
3FFD
3FFC
3FFB
b14
b13
b12
b11
RY
RY
RY
RY
E
D
C
B
RY
RY
RY
RY
3FFE
3FFD
3FFC
3FFB
b14
b13
b12
b11
b14
b13
b12
b11
b14
b13
b12
b11
SBE
SBD
SBC
SBB
SBFF
SBFF
SBFF
SBFF
E
D
C
B
b10
b9
b8
b7
RX
RX
RX
RX
A
9
8
7
RX
RX
RX
RX
3FFA
3FF9
3FF8
3FF7
b10
b9
b8
b7
RY
RY
RY
RY
A
9
8
7
RY
RY
RY
RY
3FFA
3FF9
3FF8
3FF7
b10
b9
b8
b7
b10
b9
b8
b7
b10
b9
b8
b7
SBA
SB9
SB8
SB7
SBFF
SBFF
SBFF
SBFF
A
9
8
7
b6
b5
b4
b3
RX
RX
RX
RX
6
5
4
3
RX
RX
RX
RX
3FF6
3FF5
3FF4
3FF3
b6
b5
b4
b3
RY
RY
RY
RY
6
5
4
3
RY
RY
RY
RY
3FF6
3FF5
3FF4
3FF3
b6
b5
b4
b3
b6
b5
b4
b3
b6
b5
b4
b3
SB6
SB5
SB4
SB3
SBFF
SBFF
SBFF
SBFF
6
5
4
3
b2
b1
b0
RX
RX
RX
2
1
0
RX
RX
RX
3FF2
3FF1
3FF0
b2
b1
b0
RY
RY
RY
2
1
0
RY
RY
RY
3FF2
3FF1
3FF0
b2
b1
b0
b2
b1
b0
b2
b1
b0
SB2
SB1
SB0
SBFF
SBFF
SBFF
2
1
0