List of Error Codes

The following table lists the error codes, error definitions and causes, and actions for the errors that occur in the processing for
data communication between the Motion module and external devices or occur by processing requests from the CPU module
on the own station.
Error codes are displayed in the [Error Information] tab in the "Module Diagnostics" window of the Motion module. ( Page
127 Error Information)
Error
Error definition and causes
code
1124H
• The default gateway is not set correctly.
• The gateway IP address is not set
correctly.
• The default gateway/gateway IP address
(network address after the subnet mask)
is different from that of the IP address of
the own node.
1128H
The port number is incorrect.
1129H
System error
112DH to
System error
112EH
1134H
System error
1152H
The IP address is not set correctly.
1155H
• The specified connection was already
closed in TCP/IP communications.
• Open processing is not performed.
1157H
• The specified connection was already
closed in UDP/IP communications.
• Open processing is not performed.
1158H
System error
1166H
System error
1167H
Unsent data found, but could not be sent.
1800H
• An error occurred in the SDO
communication.
• Issued a large quantity of SLMP
requests at a time.
• Issued an SLMP request for a slave
emulation enabled axis.
8 TROUBLESHOOTING
146
8.5 List of Error Codes
Action
• Correct the default gateway IP address.
• Set the same network address as that of the IP address.
Correct the port number.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Correct the IP addresses.
• Perform the open processing for the specified connection.
• Check if the open processing has been performed in the external
device.
• Perform the open processing for the specified connection.
• Check if the open processing has been performed in the external
device.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
• Check the settings for connection with the external device.
• Check the operation of the external device or switching hub.
• Since there may be congestion of packets on the line, send data
after a certain period of time.
• Check if the device cable is disconnected.
• Check that there is no connection failure with the switching hub.
• Execute the communication test, and if the test was completed
with an error, take corrective action.
• Remove error factors according to the SDO error code.
• Reduce the number of SLMP requests issued, or correct the
program to not to issue a new request until a response has been
returned.
• Correct the program to not to issue an SLMP request when slave
emulation is enabled.
Detailed information 1
Detailed information 2
■Parameter information
• Parameter type
• Intelligent module No.
• Parameter No.
• Network No.
• Station No.
■
■Parameter information
• Parameter type
• Intelligent module No.
• Parameter No.
• Network No.
• Station No.
■

Advertisement