Event List - Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

8.7

Event List

This section lists the events which occur in CC-Link IE TSN.
The event history is displayed when the [Event History] button in the [Error Information] tab in the "Module Diagnostics"
window of the Motion module is clicked. ( Page 127 Error Information)
System
Event
Description
code
00800
Link-down
00801
Link-down
00907
Divided messages receive timeout error
00C27
Transient reception error
00C28
<<Own station>> Receive frame error Line status
warning level
00C29
<<Other station>> Receive frame error Line status
warning level
00C30
<<Other station>> Parameter error occurrence
00C31
<<Other station>> Moderate/major error occurrence
00C32
<<Other station>> Minor error occurrence
00C33
Master station/sub-master station duplication error
00C34
Station duplication occurrence
00C35
Receive parameter error occurrence (station number
out of range)
00C36
Receive parameter error occurrence (station type
mismatch)
00C37
<<Own station>> Receive frame error Line status
warning level
00C39
<<Other station>> Receive frame error Line status
warning level
00C3B
Control master station duplication occurrence
00C40
Device station parameter automatic setting:
Interruption
00C41
Device station parameter automatic setting:
Parameter update interruption
00C42
Device station parameter automatic setting: System
error
00C43
Device station parameter automatic setting:
Transmission timeout
00C44
Device station parameter automatic setting: Receive
timeout
00C46
Device station parameter automatic setting: SLMP
transmission error
00C47
Device station parameter automatic setting: CPU
module access failure
00C48
Device station parameter automatic setting: No target
station parameter
00C70
CANopen initialization failure
00C72
Maximum response time mismatch for the time
managed polling method
00C80
Detection of device station that does not support the
CC-Link IE TSN Protocol version 2.0
8 TROUBLESHOOTING
166
8.7 Event List
Cause
The system was linked down by removing a device (such as an external device).
Link-down occurred when a network cable connected to an external device was
disconnected.
• Sufficient data for the data length could not be received.
• The remaining part of the divided message could not be received.
Frequency of transient transmission to the own station is too high and transient reception
failed.
A receive frame error (line status: warning level) has occurred.
A receive frame error (line status: warning level) has occurred.
A parameter error has occurred in other station
A moderate/major error has occurred in other station.
A minor error has occurred in other station.
Master station/sub-master station duplication has occurred on the network.
Station number duplication has occurred on the network.
An error of parameter (station number out of range) received from the master station/
control station has been detected.
An error of parameter (station type mismatch) received from the master station/control
station has been detected.
A receive frame error (line status: warning level) has occurred.
A receive frame error (line status: warning level) has occurred.
2 or more control master stations have been detected on the same line when the
multimaster function is used.
An abnormal response was received from the device station, and device station
parameter automatic setting processing was interrupted. (For details on device station
response codes, refer to the manual for the device station.)
An abnormal response was received from the device station, and parameter update
processing for the device station parameter automatic setting was interrupted. (For
details on device station response codes, refer to the manual for the device station.)
An error occurred while the device station parameter automatic setting was executing.
Transmission timed out while communicating with the device station parameter
automatic setting.
The specified period of time expired without receiving while communicating with the
device station parameter automatic setting.
An error occurred while transmitting SLMP for the device station parameter automatic
setting.
Access to the CPU module failed during device station parameter automatic setting.
When executing device stations parameter automatic setting, the target device station
parameter file was not stored in the CPU module.
A communication error occurred in the initialization processing of CANopen.
A maximum response time mismatch was detected for the time managed polling
method.
Update the engineering tool and the device stations to the latest version.
A device station that does not support the CC-Link IE TSN Protocol version 2.0 was
detected.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-40ssc-gMelsec iq-f fx5-80ssc-g

Table of Contents