Setting items
• Simple Display: Click the [Simple Display] button to display a narrow portion of items. Use for operation with default settings
or the minimum required settings. (Default)
• Detailed Display: Click the [Detailed display] button to display all items.
Simple
Detailed
Description
display
display
Assignment
Select a link device assignment method.
Method
• Points/Start: Enter the numbers of points and start numbers of link
• Start/End: Enter the start and end numbers of link devices.
No.
The total number of device stations set in the "CC-Link IE TSN
Configuration" window is displayed.
Model Name
The module model name is displayed.
To set a module where the profile is not registered, select it from the
"General CC-Link IE TSN Module" list or register the profile before setting
the model name.
For how to register a profile, refer to the following.
GX Works3 Operating Manual
STA#
Enter the station number of each device station connected to the network.
Station numbers do not need to be set consecutively, but must be unique.
Station Type
Set the station types. Select the station types same as those of the modules
connected to the network.
Motion control station
Use the profile to enable selection of the station to be used as the target for
Motion control.
Page 35 Setting the Motion control station
*1
RX Setting
Assign RX/RY points in increments of 16. (Page 26 Communications
using RX, RY, RWr, and RWw)
*1
RY Setting
Modules with settings provided by profile are automatically set from selected
models. (Excluding modules with a number of points that is not fixed)
This setting is not available for Motion control stations.
RWw Setting
Assign RWw/RWr points in increments of 4. (Page 26 Communications
using RX, RY, RWr, and RWw)
RWr Setting
Modules with settings provided by profile are automatically set from selected
models. (Excluding modules with a number of points that is not fixed)
Motion control stations are fixed to 40 points.
Parameter Automatic Setting
Set whether to set the parameters of each device station automatically.
This cannot be set for extension modules. However, the parameter
automatic setting of extension modules is interlocked with the settings of the
connected main module.
PDO Mapping Setting
Sets the PDO mapping for standard stations that support CANopen
communication. This setting is not available for Motion control stations.
(Page 117 PDO mapping setting)
IP Address
Set the IP address of a station that performs cyclic transmission.
Subnet Mask
Set a subnet mask to identify a network address.
Set the same value for the master station and device station. Even if a
device station has a different subnet mask from the master station, it does
not result in an input error.
If 255.255.255.255 is set, leave it empty.
Default Gateway
Set the default gateway address to connect to the external network.
devices.
Setting range
• Points/Start
• Start/End
(Default: Points/Start)
FX5-40SSC-G
• Master station: Fixed to "0"
• Device station: 1 to 20
FX5-80SSC-G
• Master station: Fixed to "0"
• Device station: 1 to 24
(Default: Serial number of added stations)
• Master Station
• Remote Station
(Default: Varies depending on the set module)
• Target for Motion control
• Not a target for Motion control
(Default: Do Not check)
• Number of points: 16 to 8192
• Start: 0H to 1FF0H
• End: FH to 1FFFH
(Default: Varies depending on the set module)
• Number of points: 4 to 1024
• Start: 0H to 3FCH
• End: 3H to 3FFH
(Default: Varies depending on the set module)
• Check: Automatically set parameters
• Do Not check: Do not automatically set
parameters
(Default: Do Not check)
0.0.0.1 to 223.255.255.254
(Default: The first to third octets have the
same values as the master station, the fourth
octet has a serial number from 1 to 254)
• 0.0.0.1 to 255.255.255.255
• Empty
(Default: The same value as the subnet mask
set in module parameters for the master
station)
• 0.0.0.1 to 223.255.255.254
• Empty
(Default: empty)
5 PARAMETER SETTINGS
5.5 "CC-Link IE TSN Configuration" Window