8.3

Checking the Network Status

The network status is checked and troubleshooting is performed by using the CC-Link IE TSN/CC-Link IE Field diagnostics to
check the network status and error definition and by performing an operation test to check communications.

CC-Link IE TSN/CC-Link IE Field diagnostics

For CC-Link IE TSN, perform status monitoring, operation tests, or others.
Precautions
In the following cases, the CC-Link IE TSN/CC-Link IE Field diagnostics cannot start.
• The Motion module is not connected to CPU modules specified on the "Specify Connection Destination Connection"
window.
• "Module Operation Mode" under "Application Settings" of the Motion module is not set to online mode.
• The error "The module error" (error code: 20E0H) occurs.
• The engineering tool is not connected to a station with the same communication speed as the master station.
• The network topology of the diagnostics destination does not support the version of the engineering tool or module.
Function list
The following table lists the functions of the CC-Link IE TSN/CC-Link IE Field diagnostics.
: Diagnosed : Diagnosed with restrictions : Not diagnosed
Function type
Function
Network status
Network map
monitor function
Selected Station
Communication Status
Monitor
Data Unlinked
Operation test/
Communication Test
execution function
Remote Operation
Description
• Displays the network configuration of CC-Link IE
TSN. This function displays the current status of
the same network as a network map, and displays
the Ethernet cable connection status, IP address
duplication, and station disconnection status. A
network map to be displayed is automatically
generated from the current configuration on the
network.
• Whether an error occurred in any of the devices
and Ethernet cables that configure the network
can be checked. In addition, the operating status
of a station set in the network parameters can be
checked.
• Displays the module status and communication
status of the selected station. If an error occurred
in the module, this function displays diagnostic
information such as the cause of the error and
corrective action.
• Detailed error definition of the selected station and
corrective action for the error can be checked.
• Displays a station with its setting existing in the
network parameters but not displayed in the
network map (a station that has never joined the
network).
• This function can check the non-existence of a
station set in the network parameter.
• This test specifies the network number and station
number or the IP address to check whether
transient transmission can be performed from the
connected station (own station) to the
communication destination.
• Transient transmission to the specified
communication destination (on the same network
only) can be checked.
This function can remotely operate (RUN, STOP,
and RESET) the CPU module and slave module.
Connection
Reference
destination of
engineering tool
Master station
Page 132 "CC-Link IE
TSN/CC-Link IE Field
Diagnostics" window
Page 136
Communication test
*1
Page 137 Remote
operation
8 TROUBLESHOOTING
8.3 Checking the Network Status
8
129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-40ssc-gMelsec iq-f fx5-80ssc-g

Table of Contents