Troubleshooting
This function checks the status of modules and networks by executing diagnostics and operation tests using the engineering
tool.
Function
CC-Link IE TSN/CC-Link IE Field
diagnostics
Communication test
Others
Function
"CC-Link IE TSN
Parameter setting of a
Configuration"
device station
window
Detection of
connected/
disconnected devices
Parameter processing
of a device station
Command execution
to device stations
Reserved station setting
Error invalid station setting
Device station parameter automatic
setting
3 FUNCTIONS
24
3.1 Function List
Description
Monitors the status of CC-Link IE TSN. The network maps,
stations where data link is not operating, selected station
communication status monitor, and others are displayed on
the engineering tool.
Checks if transient transmission data can be properly routed
from the own station to the communication target.
Description
Sets parameters of device stations (the number of points and
assignment of link devices) in the master station.
Detects connected device stations, and the stations are
displayed on the "CC-Link IE TSN Configuration" window.
Reads and saves the parameters from the device station, and
writes the saved parameters to the device station.
Executes commands (Error clear request, Error history clear
request) to a device station.
Reserved stations are device stations to be included among
the stations in the network for future extension and set in the
parameters. These stations are not connected to actual
networks, and are not regarded as faulty stations even if they
are not connected.
By setting a reserved station, link device assignment will not
change even if the device station is connected (or the
reservation is cleared). Therefore, modification of the program
is not required.
An error invalid station is a device station that is set to be not
detected as a faulty station by the master station. It is also set
when a device station is to be replaced during data link.
Saves parameters of the device station to the master station,
and sets the parameters automatically when the device
station is connected or returned to the network.
Availability
Reference
Standard
Motion
station
control
station
Page 129 CC-
Link IE TSN/CC-
Link IE Field
diagnostics
Page 136
Communication
test
Availability
Reference
Standard
Motion
station
control
station
Page 108
Parameter
setting of a
device station
Page 111
Connected/
Disconnected
module detection
Page 113
Parameter
processing of a
device station
Page 115
Command
execution to
device stations
Page 108 "CC-
Link IE TSN
Configuration"
Window
Page 108 "CC-
Link IE TSN
Configuration"
Window
Page 51 Device
station parameter
automatic setting