10.6

List of Error Codes

This section lists the error codes, error details and causes, and actions for the errors that occur in the processing for data
communications between the FX5-ENET and external devices or that are caused by processing requests from the CPU
module on the own station.
The FX5-ENET has the following error codes.
Type

CC-Link IE Field Network Basic error

Module error
Ethernet communication error
CC-Link IE Field Network Basic error
If an error occurs with CC-Link IE Field Network Basic, the error code can be confirmed with CC-Link IE Field Network Basic
diagnostics. ( Page 104 CC-Link IE Field Network Basic Diagnostics) The error codes are stored in 'Latest error code'
(Un\G29).
Error code Error name
CFC0H
Cyclic transmission error
(master station)
CFC1H
Cyclic transmission error
(master station)
CFC8H
Cyclic transmission error
(master station)
CFC9H
Cyclic transmission error
(master station)
CFD0H
Master station error
CFD1H
Master station error
CFE0H
Cyclic transmission error
(remote station)
CFE1H
Cyclic transmission error
(remote station)
CFE8H
Cyclic transmission error
(remote station)
CFE9H
Cyclic transmission error
(remote station)
CFF0H
Remote station error
10 TROUBLESHOOTING
110
10.6 List of Error Codes
Error code
CFC0H to CFF0H
0800H to 480EH
C012H to CFBFH
Error details and causes
Multiple master stations are on the same
network address so that cyclic transmission
cannot be executed.
An error occurs during cyclic transmission
so that cyclic transmission cannot be
executed.
There is a remote stations that is controlled
by the other master station so that cyclic
transmission cannot be executed.
There is a remote station that has the same
IP address on the same network address so
that cyclic transmission cannot be
executed.
The port number (61450) used by CC-Link
IE Field Network Basic is already in use.
An incorrect value is set by the subnet
mask.
Cyclic transmission is executed for the
remote station that is controlled by the other
master station.
The master station specifies the number of
occupied stations that cannot be handled.
No response from the remote station.
There is a remote station that has the same
IP address on the same network address.
An error occurs in the remote station.
Reference
Page 110
Page 111
Page 119
Action
Confirm the master station on the network.
• Take measures to reduce noise.
• If the error is displayed again after re-execution, please consult
your local Mitsubishi representative.
• Confirm the master station on the network.
• Confirm the remote station with error.
• Confirm the remote station on the network.
• Confirm the remote station with error.
Recheck the port number used in the Ethernet function.
Correct parameter shown in cause.
• Confirm the master station on the network.
• Confirm the remote station with error.
Recheck the number of occupied stations setting of the parameter
of the master station (network configuration setting).
• Recheck the disconnection detection setting of the remote
station of the parameter of the master station (network
configuration setting).
• Confirm the remote station on the network.
• Confirm the disconnection remote station.
• Take measures to reduce noise.
Confirm the remote station with error.
Confirm the remote station with error.