3.7.7. Selecting the Generator Framing Reference

REFERENCE MODE
Ref auto
Ref input
Ref external
For proper operation the SDI input video and the external colour reference must be
vertically in phase.

3.7.8. Turning on the Daylight Saving Time Compensation

DAYLIGHT SAVING
Dst time off
Dst time on

3.7.9. Configuring The General Purpose Inputs and Outputs

A 9 pin D connector located on the rear panel labeled PARALLEL provides control inputs and output
for remote control of some of the model 8010TM-IRIG functions. There are also two open collector
outputs that can be assigned to a variety of functions. The pinout of the D connector when the
8010TM-IRIG is not in the time rctl mode is shown in Table 2-3.
OPERATION
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
The REFERENCE MODE menu item is used to set whether the internal
timing of the 8010TM-IRIG will be locked to the input video or the
External Colour Reference input. The updating of the generator clock,
character displays and LTC phasing are in turn locked to the input
timing of the 8010TM-IRIG.
Select auto to allow the 8010TM-IRIG to select its reference
automatically.
present the 8010TM-IRIG will lock to the SDI input video.
Select input to reference the 8010TM-IRIG to the input video.
Select external to reference the 8010TM-IRIG to the colour reference
input. This setting will allow the LTC phase output of the 8010TM-IRIG
to remain locked to the reference when an SDI input signal is not
present.
When the generator is operating in the Time date mode, the DAYLIGHT
SAVING menu item is used to select whether the time will be
compensated for Daylight Saving time or not.
Select Dst time on to compensate for Daylight saving time. This setting
should be used during the period when daylight saving time is in effect.
When this setting is used 1 hour will be subtracted from the Time zone
offset value when the 8010TM-IRIG converts between UTC and local
time.
Select Dst time off to turn off compensation for Daylight saving time.
This setting should be used during the period when daylight saving time
is not in effect.