Irig Code Connections; Tally Connections; Serial Port Connections; Table 2-1: Serial Control Pin Definitions - Rs-232 Dce Configuration - evertz 8010TM IRIG Instruction Manual

Sdi time code master with irig reader
Hide thumbs Also See for 8010TM IRIG:
Table of Contents

Advertisement

2.1.4. IRIG Code Connections

IRIG IN:
A female XLR connector for input of IRIG B serial time code for the reader (Balanced)

2.1.5. Tally Connections

FAULT TALLY OUT:
open circuit when the 8010TM-IRIG is processing video normally. The output will be
grounded when the optional SDI bypass relay is active.

2.1.6. Serial Port Connections

SERIAL:
A 9 pin female 'D' connector for connection to the RS-232/RS-422 serial
communications. See section 5.2.2 for the information on configuring the port for various
applications.
On the 8010TM-IRIG this port is configured at the factory for configured for a 'straight through RS-232
connection to a PC COM port. In this configuration it can be used for uploading firmware to the unit or
serial remote control.
configuration.
Pin

Table 2-1: Serial Control Pin Definitions - RS-232 DCE Configuration

This port can also be configured as an RS-422 tributary port for serial control applications. See section
5.2.2 for information on re-configuring the serial port. Table 2-2 shows the pinout of the serial port in its
RS-422 Controller configuration.
INSTALLATION
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
A BNC connector for output of a SMPTE 269M fault tally. The output will be
Table 2-1 shows the pinout of the serial port in its default RS-232 DCE
Name
#
1
GND
Chassis ground
2
TxD
RS-232 Transmit Output
3
RxD
RS-232 Receive Input
4
5
Sig Gnd
RS-232 Signal Ground
6
7
RTS
RS-232 RTS Input
8
CTS
RS-232 CTS Output
9
Description
Revision 1.4.1
Page 2-2

Advertisement

Table of Contents
loading

Table of Contents