Generator Commands; Table 4-11: Generator Modes - evertz 8010TM IRIG Instruction Manual

Sdi time code master with irig reader
Hide thumbs Also See for 8010TM IRIG:
Table of Contents

Advertisement

67
Sense Broadcast Block
6C
Sense Reader Time Zone Adjust
4C
Select Reader Time Zone Adjust
4.9.

GENERATOR COMMANDS

A0
Sense Generator Mode
80
Select Generator Mode
A1
Sense VITC Generator Lines
81
Preset VITC Generator Lines
To generate VITC on only one line set Line 1 and Line 2 equal. Line numbers are packed BCD
format. Valid lines at 6 to 21 for PAL and 10 to 20 for NTSC.
SERIAL PROTOCOL
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
Rdr No.
Rdr No. +1 byte
TIME ZONE ADJUST
00
01
1 byte
MODE
00
01
02
03
04
05

Table 4-11: Generator Modes

2 bytes
Revision 1.4.1
Returns the broadcast block as
defined by the Define Broadcast
Mode command above.
Returns 1 byte as defined below.
Sets the Time Zone Adjust
parameter for the specified Reader
DESCRIPTION
Display UTC Reader time
Display Local Reader time
Returns 1 byte as defined below.
Selects the mode of the generator.
DESCRIPTION
TIME
UB
TIME
DATA
TIME
RDR TIME
TIME
RDR UB
TIME
DATE
CONVERT 25 ⇔ 30
TIME
RCTL
Returns 2 bytes as defined below.
Presets the line numbers of the
VITC generator
Page 4-13