JAM
Indicates that the generator is operating in the continuous Jam Sync Mode.
U/B TRANSFER Indicates that the Generator User Bits are being transferred from the active reader's
time or user bits.
IRIG READER Indicates that IRIG reader is reading valid code.
VITC READER Indicates that VITC reader is reading valid code.
3.2.

FRONT PANEL DISPLAY FUNCTIONS

3.2.1. Front Panel Displays

The DISPLAY key is used to select which data is being displayed in the alphanumeric display. Each
time the DISPLAY key is pressed, the front panel display cycles to the next available display. The
leftmost characters of the display indicate what is being displayed as follows:
GTM
12:34:56:00
GUB
12 34 56 78
ITM
12:34:56:00
IUB
12 34 56 78
VTM
12:34:56:00
VUB
12 34 56 78
When the reader time or user bits are being displayed the active reader will be indicated by an asterisk
(e.g. ITM* indicates that the IRIG reader is active. VTC* indicates that the VITC reader is active) See
section 3.5.1 for more information on selecting which reader is active.
There are also some extended displays which are accessible by pressing the SHIFT + DISPLAY keys.
Press SHIFT + DISPLAY to return to the normal displays. At this time the extended displays are:
OFFS 00:00:00:00
REVT 00:00:00:00
GEVT 00:00:00:00
JAM@ 00:00:00:00

3.2.2. Special Front Panel Indicators

The following special indicators are used between the seconds and frames digits of the front panel time
display to identify non-drop frame and drop frame code (NTSC only)
Non Drop Frame
Drop Frame (NTSC) Period (.)
The following special indicators are used between the hours and minutes digits of the front panel time
display when the 8010TM-IRIG is in Time/Date mode generating local time and the time s being
adjusted for Daylight Saving Time
OPERATION
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
Generator Time information
Generator User Bit information
IRIG Reader Time information
IRIG Reader User Bit information
VITC Reader Time information
VITC Reader User Bit information
Jam Sync Offset register
Time at which Reader Time Event GPO will occur
Time at which Generator Time Event GPO will occur
Reader Time at which a momentarily jam will occur