3.7.9.2. Assigning the Functions of the General Purpose Inputs

When the GEN MODE is NOT set to time rctl there are four dedicated remote control input pins and two
user programmable inputs. The dedicated input functions are as follows:
VCG ON/OFF Provides an alternate method of turning the character inserter generator On and Off.
The character inserter is toggled On or Off by a high to low transition on this input. This
input has equal priority with the front panel CHAR GEN ON/OFF key.
VITC ENABLE
Provides an alternate method of turning the VITC generator On and Off. The VITC
generator is turned On by a high to low transition on this input, and turned Off by a low to
high transition.
BYPASS
When closed to ground this input activates the SDI bypass relay.
JAM SYNC
Provides an alternate method of syncing the generator time of the active reader time
when the unit is not in the convert mode. Momentarily closing this input to ground and
releasing it will perform a synchronization to the reader time.
The GPI1 ASSIGNMENT and GPI2 ASSIGNMENT menu items are used to select the functions of the
other two general purpose inputs (GPI 1 and GPI 2). The operation of both menus is identical so only
the GPI1 Assignment menu will be shown.
GPI1 ASSIGNMENT
Gpi1 = ltc active
Gpi1 = vitc active
Gpi1 = gen hold
Gpi1 = gen set
OPERATION
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
The following descriptions indicate the how the GPI will function with
each setting. (8010TM models only)
Ltc active
Provides an alternate method of selecting the LTC
reader as the active reader. The LTC reader is selected by a
high to low transition on this input, and deselected by a low to
high transition. This menu item is available only on the 8010TM
Vitc active
Provides an alternate method of selecting the VITC
reader as the active reader. The VITC reader is selected by a
high to low transition on this input, and deselected by a low to
high transition.
Gen hold
Provides an alternate method of selecting the Generator
Hold function. The generator Hold function is selected by a high
to low transition on this input, and deselected by a low to high
transition.
Gen set
Provides an alternate method of selecting the Generator
Set function. The generator Set function is selected by a high to
low transition on this input, and deselected by a low to high
transition. When this input is closed to ground the last entered
time value is entered into the Generator again.