3.4.16. Configuring how the Continuous Jam Sync Mode Works
when there is no Reader Code
GEN NO CODE JAM
No code jam run
No code jam hold
No code jam mute
3.4.17. Configuring Whether the Generator will Output Local Time
or UTC Time in Time/Date Modes
GEN TIME ZONE ADJ
Gtm zone adj utc
Gtm zone adj loc
OPERATION
Model 8010TM-IRIG SDI Time Code Master with IRIG Reader Manual
The GEN NO CODE JAM item controls the operation of the continuous
jam sync mode when there is no incoming code.
Select No code jam run when you want the generator to free run when
there is no incoming Reader code. When the reader code resumes,
the generator will re-jam to the incoming code. Using this mode will
allow the user to repair large dropouts in the incoming code. The
generated code will be continuous if the incoming code is also
continuous.
Select No code jam hold when you want the generator to stop when
there is no incoming Reader code. When the reader code resumes,
the generator will re-jam to the incoming code. Use this mode if you
want the output of the generator to stop on the last number read when
you stop the tape machine supplying the incoming code to the reader.
Select No code jam mute when you want to turn off the generator when
there is no incoming Reader code. The generator time will stop at the
last number read. When the reader code resumes, the generator will
turn on and re-jam to the incoming code. Use this mode if you want the
output of the generator to turn off completely when you stop the tape
machine supplying the incoming code to the reader.
When the GEN MODE is set to TIME DATE, the generator internal time
clock
runs
GEN TIME ZONE ADJ menu item is used to select whether the
Generator will output UTC or UTC adjusted by the programmed Time
Zone Offset (Local Time). The local time will also be adjusted by the
daylight savings time adjustment if daylight savings time is in effect.
See section 3.4.8 for a discussion of daylight saving time features of
the 8010TM-IRIG.
Select Gtm zone adj utc to configure the generator to output its time as
UTC
Select Gtm zone adj loc to configure the generator to output its time as
UTC adjusted by the programmed Time Zone Offset and Daylight
saving adjustment if DST Time is On.(Local Time)