To reconfigure the serial port it is necessary to unplug the SDI Time Code Master and remove the top
cover. Figure 5-1 shows the settings of jumper block J9 on the main circuit board for the various
configurations available. The pinouts corresponding to RS-232 DCE and RS-422 controller
configurations are given in Chapter 2. It is impossible to tell whether the serial port pinout has been
altered without opening the unit for inspection.

Figure 5-1: Jumper Settings for Serial Port Configurations

5.3.

UPGRADING THE FIRMWARE

5.3.1. Overview

The SDI Time Code Master contains firmware in a FLASH ROM device. From time to time firmware
updates may be provided to add additional features to the unit. The following procedure will allow you
to upload new firmware from your computer.
You will need the following equipment in order to update the Firmware:
PC with available communications port. The communication speed is 19200 baud. A 486 PC or
better with a 16550 UART based communications port is recommended.