Selecting The Generator Framing Reference; Adjusting The Output Level Of The Ltc Generators - evertz HD9010TM-IRIG Instruction Manual

Hdtv time code master with irig-b reader
Table of Contents

Advertisement

3.7.2. Selecting the Generator Framing Reference

REFERENCE MODE
Ref: input
Ref: tri-lvl
Ref: Bi-lvl
Regardless of the setting of this menu control the HD9010TM requires a stable
video input for normal operation.

3.7.3. Adjusting the Output Level of the LTC Generators

LTC LEVEL
Ltc Level =xx
AUX LTC LEVEL
Aux Ltc Level =xx
OPERATION
HD9010TM-IRIG HDTV Time Code Master / IRIG-B Reader Manual
The REFERENCE MODE menu item is used to set whether the internal
timing of the HD9010TM-IRIG will be locked to the input video or the
External Reference input.
character displays and LTC phasing, and output video timing reference
signals (TRS) are in turn locked to the internal timing reference of the
HD9010TM-IRIG.
Select input to reference the HD9010TM-IRIG to the input video. This
setting will cause the internal timing reference of the HD9010TM-IRIG
to become disrupted and unlocked when an HD input signal is not
present. This may cause disturbances in the output video, but is the
preferred method when you cannot time the input video to the reference
within one line.
Select tri-lvl to reference the HD9010TM-IRIG to a tri-level sync signal
applied to the GENLOCK input.
HD9010TM-IRIG to a bi-level sync signal applied to the GENLOCK
input. These settings will allow the internal timing reference of the
HD9010TM-IRIG to remain locked to the reference when an HD input
signal is not present, providing a stable video output. The input video
must be timed to the sync reference within one horizontal line period for
proper alignment of the picture content on the output video. The format
of the reference sync signal must be in accordance with the standards
shown in Table 2-4.
The LTC LEVEL menu item is used to adjust amplitude of the main LTC
output. Turn the shaft encoder to adjust. The recommended output
level setting is 35, which is approximately 1 volt peak to peak.
The AUX LTC LEVEL menu item is used to adjust amplitude of the
auxiliary LTC output.
recommended output level setting is 35, which is approximately 1 volt
peak to peak.
Revision 2.1
The updating of the generator clock,
Select bi-lvl to reference the
Turn the shaft encoder to adjust.
The