Parameter
Interval (Sec.)
Health Mail
Sending Interval
Test
Step 3
Click Apply to complete the settings.

4.11.12 SNMP

You can connect the Device with some software such as MIB Builder and MG-SOFT MIB Browser to
manage and control the Device from the software.
Prerequisites
● Install the software that can manage and control the SNMP, such as MIB Builder and MG-SOFT
MIB Browser
● Obtain the MIB files that correspond to the current version from the technical support.
This function is for some series only.
Procedure
Step 1
Select Main Menu > NETWORK > SNMP.
The SNMP interface is displayed. See Figure 4-231.
Description
This is the interval that the system sends an email for the same type of
alarm event, which means, the system does not send emails caused by
frequent alarm events.
The value ranges from 0 to 3600. 0 means that there is no interval.
Enable the health test function. The system can send a test email to
check the connection.
This is the interval that the system sends a health test email.
The value ranges from 30 to 1440. 0 means that there is no interval.
Click Test to test the email sending function. If the configuration is
correct, the receiver's email account will receive the email.
Before testing, click Apply to save the settings.