between two people reaches the parameter setting, an alarm will be triggered.
Procedure
Select Main Menu > AI > Parameters > Stereo Analysis.
Step 1
Step 2
Select a channel and click Add.
Step 3
Select Enable and set Type to People Approach Detection.
Step 4
Click
Step 5
Configure parameters.
Parameter
Sensitivity
Duration
Repeat Alarm Time
Interval Threshold
Step 6
Click OK.
4.7.1.4.2 Fall Detection
When someone falls from a height in the detection area and the duration of the action is greater
than the minimum duration set by the parameter, an alarm will be triggered.
Procedure
Step 1
Select Main Menu > AI > Parameters > Stereo Analysis.
Step 2
Select a channel and click Add.
Step 3
Select Enable and set Type to Fall Detection.
Step 4
Click
Step 5
Configure parameters.
Parameter
Sensitivity
Duration
Repeat Alarm Time
Step 6
Click OK.
4.7.1.4.3 People No. Exception Detection
When the number of people and alarm type are reached in the same detection area, an alarm will be
triggered.
Procedure
Step 1
Select Main Menu > AI > Parameters > Stereo Analysis.
, and then click and hold left mouse key to draw an area on the screen.
Table 4-30
Description
Set alarm sensitivity.
Set the minimum time of triggering an alarm when people approach.
Set repeat alarm time. If the alarm status continues, an alarm will be
trigger again when repeat alarm time is reached.
When the interval between people in the area is greater than or less
than the set interval threshold, an alarm will be triggered.
, and then click and hold left mouse key to draw an area on the screen.
Table 4-31
Description
Set alarm sensitivity.
Set the minimum time of triggering an alarm when people fall.
Set repeat alarm time. If the alarm status continues, an alarm will be
trigger again when repeat alarm time is reached.