Table of Contents

Advertisement

Parameter
Name
Duration
Filter target
3) Draw a rule. Left click mouse to draw a zone, until you draw a rectangle, you can right
click mouse.
4) Click OK to complete the rule setting.
Step 3
Click
Click Apply to complete the setup.
Step 4

4.7.2.4.6 Parking

Background Information
When the detection target stays in the monitoring area for more than the set duration, the system
performs alarm linkage action.
Procedure
Step 1
In the Type drop-down list, select Parking.
The interface is shown as below. See Figure 4-149.
Description
Input customized rule name
Set the minimum time that the object stays until the alarm is triggered.
Click
to filter the target. Check the blue wireframe and adjust the size
of the area with the mouse.
Each rule can set 2 target filters (maximum size and minimum size), that is,
when the passing target is smaller than the minimum target or larger than
the maximum target, no alarm will be generated. The maximum size
should not be smaller than the minimum size.
, you can refer to "4.7.2.4.1 Tripwire" to set other parameters.
250