QMP-5101N Network Paging Wiring for Mass Notification
Figure 84:
QMP-5101N Network Master Paging Control Module Wiring to the ANC-
5000 Audio Network Controller Module
MNS - ACU
QMP-5101N Network
Master Paging Module
Wire the Paging Bus
to all other ANC-5000
Audio Network
Controller Modules
OUT to IN. See Figure
73 for more details.
OUT
IN
S - +
S - + L - +
PAGING BUS
ANC-5000 Audio
Network Controller
Module in the
MNS (ACU)
132
-
-
S
MIC
PTT
TWISTED
SHIELDED
PAIR CABLE
NOT USED
RS-485
S - +
S - +
PTT
MIC
JW7
JW8
Jumpers JW7 and JW8
must be installed at all
times.
TWISTED
QMP-5101N Network
SHIELDED
Master Paging Module
PAIR
CABLE
This connec-
tion to Aux
Power is not
required when
ANC-5000 is
G.A.
installed in the
Input
Audio Card
IN
Cage
-
+
-
+
Remote
Power
Input
FX- LOC(R)
-
S
PTT
MIC
Daisy chain PTT and
MIC to next FX-LOC(R).
At the last FX-LOC(R)
QMP-5101N Paging
Mocule connect EOL
resistors (3K9 ohms
value) to + and - of
both the MIC and PTT
terminals.
-