Use The Default Configuration; Change The Default Configuration - Rockwell Automation Allen-Bradley ArmorBlock 1732E-IB8M8SOER User Manual

Ethernet/ip dual port 8-point sequence of events input and scheduled output modules
Table of Contents

Advertisement

Use the Default
Configuration
Change the Default
Configuration
When you click Change..., the Module Definition dialog is shown.
Through the Module Definition dialog, you can:
1. Select the module series.
2. Make sure the Major and Minor Revision numbers match your
module's revision.
3. Choose an Electronic Keying method.
4. On the 1732E-IB8M8SOER module, select the Connection type.
Available options are Data and Listen Only.
(This field is not available for 1732E-OB8M8SR module.)
5. Select the Timestamp Format.
On the 1732E-IB8M8SOER module, the options available are
Per Point, First In First Out, and None.
On the 1732E-OB8M8SR module, the options available are Per
Point, and None.
For more information about timestamping format, see Use the
Sequence of Events Input and Scheduled Output Modules on
page
6. On the 1732E-OB8M8SR module, select whether MAOC support
is required (Yes) or not (No).
7. Click OK to return to the General tab of the Module Properties
dialog.
8. On the General tab, you can click OK to close the Module
Properties dialog and download your configuration, or
9. Click the Connection tab to configure connection properties.
If you use the default configuration and click OK, you are done.
You can skip to Download Your Configuration on
how to download your default configuration to the controller.
If you click Change... in
Definition information. Note that the 1732E-IB8M8SOER and 1732E-
OB8M8SR modules have slightly different Module Definition dialogs.
The1732E-OB8M8SR module does not have the Connection field.
page 41
guides you through the dialog.
Select tabs on the Module Properties dialog to edit specific configuration for
your module in Studio 5000 Logix Designer software, for example the
Configuration tab.
Some of the screens that appear during this initial module configuration
process are blank (such as Module Info, Network, and Time Sync) and are not
shown here. These screens provide information and status and can be
important during online monitoring. To view these screens in use, see
Troubleshoot the Module on page
Figure 8 - Change Default Configuration
59.
Rockwell Automation Publication 1732E-UM003D-EN-E - November 2021
Chapter 6
Configure the Module Using Studio 5000 Logix Designer Software
step 4
on
page
40, you can change the Module
79.
On 1732E-IB8M8SOER
On 1732E-OB8M8SR
On 1732E-OB8M8SR
page 43
for instructions on
Figure 8 on
41