1. Name the bridge.
2. Enter the IP address.
3. Select slot 3 for the EtherNet/IP bridge.
4. Make sure the Minor Revision number
matches your module revision number.
5. Choose an Electronic Keying method.
For more information, see
page
48.
6. Click OK.
1. Select the I/O module.
2. Click OK.
Rockwell Automation Publication 1732E-UM003D-EN-E - November 2021
Chapter 6
4. The New Module dialog opens.
Configure the bridge module as illustrated below.
The local 1756-EN2T communication module will communicate with the
ArmorBlock module on Ethernet. Before you can communicate with your
module, you need to add it as a child of the 1756-EN2T communication module.
For more information about using 1756 controller and EtherNet/IP products,
see the EtherNet/IP Network Devices User Manual, publication ENET-UM006.

Add the I/O module as a child of the 1756-EN2T module

1. Right-click the Ethernet folder that appears below the 1756-EN2T bridge
you added to the I/O Configuration tree and select New Module.
2. Expand Digital in the Select Module dialog that appears.
Select the 1732E-IB8M8SOER or the 1732E-OB8M8SR module.
If the 1732E-IB8M8SOER, 1732E-OB8M8SR modules are not listed in the digital section of
the Select Module dialog, you may need to download the Add-On Profile (AOP) and
install it as an add-on to the Studio 5000 Logix Designer software. The AOP file can be
downloaded from: rok.auto/pcdc.
Configure the Module Using Studio 5000 Logix Designer Software
39