Rockwell Automation Allen-Bradley ArmorBlock 1732E-IB8M8SOER User Manual page 95

Ethernet/ip dual port 8-point sequence of events input and scheduled output modules
Table of Contents

Advertisement

Table 25 - Configuration Assembly Instance 171 Data Structure
Consumed
Bit 7
Bit 6
Byte
0
Reserved (Ignored)
1
Reserved (Ignored)
FaultMode
FaultMode
2
Ch7
Ch6
3
Reserved (Ignored)
FaultVal
FaultVal
4
Ch7
Ch6
5
Reserved (Ignored)
FaultFinal
FaultFinal
6
State Ch7
State Ch6
7
Reserved (Ignored)
ProgMode
ProgMode
8
Ch7
Ch6
9
Reserved (Ignored)
ProgVal
ProgVal
10
Ch7
Ch6
11
Reserved (Ignored)
12...15
Hold Last State Duration [0]
16...19
Hold Last State Duration [1]
20...23
Hold Last State Duration [2]
24...27
Hold Last State Duration [3]
28...31
Hold Last State Duration [4]
32...35
Hold Last State Duration [5]
36...39
Hold Last State Duration [6]
40...43
Hold Last State Duration [7]
ProgToFaultEn – Selects whether (enabled) or not (disabled) to apply the fault value when the output is
already being set to the program value when a Fault (connection timeout) occurs in Program Mode.
FaultMode – If Fault occurs (connection loss): When clear use FaultValue for Output. When set, Output
Holds Last State for HoldLastStateDuration.
Fault Value – If corresponding FaultMode bit clear, defines Output Value on Fault (connection timeout).
Not used if FaultMode bit is set.
Hold Last State Duration – If FaultMode is set (Hold Last State), this value determines the length of time
Where:
the last state is to be held prior to the FaultFinalState being applied. Valid values are 0 = Hold Forever,
and either 1, 2, 5, or 10 (indicating hold time in seconds). All other values reserved.
FaultFinalState – If FaultMode is set (Hold Last State) and HoldLastStateDuration[8] is non-zero,
determines the final Output state after the configured time out occurs.
ProgMode – If ProgramMode event occur: When clear use ProgValue for Output.
When set, Output Holds Last State.
ProgValue – If corresponding ProgMode bit clear, defines Output value on Program Mode.
Not used if ProgMode bit set.
Table 26 - Consumed Assembly Instance 174 Data Structure
Consumed
Bit 7
Bit 6
Byte
0
Data Ch7
Data Ch6
1
Reserved (Ignored)
ScheduleM
Schedule
2
ask
Mask
Ch7
Ch7
3
Reserved (Ignored)
4
Timestamp Offset
5
Schedule Timestamp
6
Schedule[0].ID
7
Schedule[0].SequenceNumber
8
Schedule[0].OutputPointSelect
9
Schedule[0].Data
Rockwell Automation Publication 1732E-UM003D-EN-E - November 2021
Bit 5
Bit 4
Bit 3
FaultMode
FaultMode
FaultMode
Ch5
Ch4
Ch3
FaultVal
FaultVal
FaultVal
Ch5
Ch4
Ch3
FaultFinal
FaultFinal
FaultFinal
State Ch5
State Ch4
State Ch3
ProgMode
ProgMode
ProgMode
Ch5
Ch4
Ch3
ProgVal
ProgVal
ProgVal
Ch5
Ch4
Ch3
Bit 5
Bit 4
Bit 3
Data Ch5
Data Ch4
Data Ch3
Schedule
Schedule
Schedule
Mask
Mask
Mask
Ch7
Ch7
Ch7
Appendix B
Data Tables
Bit 2
Bit 1
Bit 0
CRN
ProgTo
FaultEn
FaultMode
FaultMode
FaultMode
Ch2
Ch1
Ch0
FaultVal
FaultVal
FaultVal
Ch2
Ch1
Ch0
FaultFinal
FaultFinal
FaultFinal
State Ch2
State Ch1
State Ch0
ProgMode
ProgMode
ProgMode
Ch2
Ch1
Ch0
ProgVal
ProgVal
ProgVal
Ch2
Ch1
Ch0
Bit 2
Bit 1
Bit 0
Data Ch2
Data Ch1
Data Ch0
Schedule
Schedule
Schedule
Mask
Mask
Mask
Ch7
Ch7
Ch0
95