Default Parameters - Rockwell Automation SILVER Technology HARRY HI 1734-WS Installation & Operation Manual

Point i/o weigh scale module
Table of Contents

Advertisement

Approvals:

Default Parameters

Configuration Table
Gravity Correction
Motion Tolerance
Zero Tolerance
Tare Weight
Reference Weight
Span Weight
AutoZero Tolerance
Enable AutoZero
Tracking
Metric
Load Cell Sensitivity
Waversaver
Num Averages
NOTE: THE HI1734 is not compatible with HI 215IT Junction Boxes. Please ensure that the HI1734 is
installed with the HI6020IT, HI 6020JB, HI 6010IT or HI 6010JB Junction Boxes. It is compatible
with the HI 215JB without the IT functions.
Page | 10
Programmable Controller for Use in Hazardous Locations
Class I, Division 2 Groups A, B, C and D, Temp Code T6
UL, CUL Ordinary Location & CE
Data
Defaults Range
Type
1.0
FLOAT
10.0
FLOAT
999999.99
10.0
FLOAT
999999.99
0.0
FLOAT
999999.99
0.0
FLOAT
999999.99
1000.0
FLOAT
999999.99
10.0
FLOAT
999999.99
0
BYTE
1
BYTE
4
BYTE
3
BYTE
10
INT
Hardy 1734-WS Installation & Operation Manual
.9-1.2
.0001-
.0001-
.0001-
.0001-
.0001-
.0001-
0-1
0 – Off
1 - On
0-5
0 – oz
1 – lb
2 – ton
3 – g
4 – kg
5 - t
0-8
0 – 1.0 mV/V
1 – 1.5 mV/V
2 – 2.0 mV/V
3 – 2.5 mV/V
4 – 3.0 mV/V
5 – 3.5 mV/V
6 – 4.0 mV/V
7 – 4.5 mV/V
8 – 5.0 mV/V
0-5
0 – Off
1 – 7Hz
2 – 3.5 Hz
3 – 1Hz
4 – 0.5Hz
5 – 0.25Hz
1-255