2
1
3
4
Fig. Air cleaner
1. Catches
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
2020-10-27
Maintenance measures - 250 h
Every 250/750/1250/1750..... hours of operation (every
3 months)
Air cleaner - Cleaning - Change
Clean the air cleaner. Remove the main filter (3) by
undoing the catches (1), and then the cover (2).
Check that the filter element is undamaged. Clean the
element by banging it against your hand or other soft
5
object.
Then blow clean with compressed air (max 5 bars)
from the inside of the filter. Also clean the filter
housing (5) and the cover (2).
4812160801_G.pdf
Maintenance measures - 250 h
Park the roller on a level surface.
Park the roller on a level surface.
The engine must be switched off and the
The engine must be switched off and the
parking brake activated when checking or
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
adjusting the roller, unless otherwise specified.
Ensure that there is good ventilation (air
Ensure that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
carbon monoxide poisoning.
Ensure that the engine cover is fully open when
Ensure that the engine cover is fully open when
work is being carried out under it
work is being carried out under it
Replace the filter cartridge after 5 cleanings or
Replace the filter cartridge after 5 cleanings or
more frequently.
more frequently.
85