Maintenance - 50H; Air Cleaner - Emptying - Fayat Group Dynapac CC800 Instruction Manual

Table of Contents

Advertisement

Fig. Air cleaner
1. Dust trap
2020-10-27

Maintenance - 50h

Every 50 hours of operation (Weekly)
Park the roller on a level surface.
Park the roller on a level surface.
The engine must be switched off and the
The engine must be switched off and the
parking brake activated when checking or
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
adjusting the roller, unless otherwise specified.
Ensure that there is good ventilation (air
Ensure that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
carbon monoxide poisoning.
Ensure that the engine cover is fully open when
Ensure that the engine cover is fully open when
work is being carried out under it
work is being carried out under it
After the first 50 hours of operation, the oil filters
After the first 50 hours of operation, the oil filters
should be changed.
should be changed.

Air cleaner - emptying

Empty the air cleaner dust trap (1) through pressing
the rubber bellows using the fingers. Check also that
the air hoses are intact.
Clean the air cleaner when operated in extremely
dusty environments .
1
Refer also to the section in the manual on operation.
4812160801_G.pdf
Maintenance - 50h
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac cc900Dynapac cc1000Dynapac cc900g

Table of Contents