6700 Series - Scsi Tape Drive Test Error Codes; 7000 Series - Server Manager/R Board Test Error Codes - Compaq ProSignia 200 Manual

Hide thumbs Also See for ProSignia 200:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-30
Diagnostics Tools
6700 Series -
SCSI Tape Drive Test Error Codes
The 6700 series of Diagnostic error codes identify failures with tape cartridge,
tape drive, tape drive cabling, adapter board, or system board assembly.
Corrective action may require replacement of the tape cartridge, tape drive
cabling, adapter board, tape drive, or system board assembly.
Error Code Range
6700-xx ... 6728-xx A defective tape cartridge, loose cable connections, or defective cable
7000 Series -
Server Manager/R Board Test Error Codes
The 7000 series of Diagnostic error codes identify failures with the Server Manager/R
board. Corrective action may require replacement of the Server Manager/R board, the
Integrated 2400-baud modem, voice ROM, or battery on the Server Manager/R board.
Error Code Range
7000-xx ... 7046-xx The Server Manager/R board may require replacement.
7051-xx ... 7057-xx The Server Manager/R board Enhanced 2400-Baud Integrated Modem
7061-xx ... 7062-xx The Server Manager/R board Voice ROM may require replacement.
7078-xx ... 7079-xx The Server Manager/R board battery may require replacement.
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
SCSI Tape Drive Test Error Codes
connections may cause error messages. The tape drive, the tape
adapter board, or the system board may require replacement.
Server Manager/R Board Test Error Codes
may require replacement.
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Possible Corrective Action
Possible Corrective Action

Advertisement