POST Error Messages
Error Code
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical drive
X.
Select F1 to continue
- drive array will
remain disabled.
Select F2 to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
1790-Disk 0 Error
1790-Disk 0
Configuration Error
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Audible
Beeps
L=Long
S=Short
None
Hard drive X failed or
cable is loose or defective.
After system restart,
message reminds you that
drive X is defective and
fault tolerance is being
used.
None
Cable or hard drive
failure.
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Probable Source of
Problem
1. Replace drive X as
soon as possible.
2. Check loose
cables.
3. Replace defective
cables.
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want
to replace the
drives now, press
F2.
Run the System
Configuration Utility.
Run the System
Configuration Utility
and Diagnostics.
Compaq ProSignia 200 Server Reference Guide
8-17
Action
continued

Advertisement