8-38
Diagnostics Tools
DAAD Diagnostic Messages
Message
Accelerator status:
Valid data found at
reset
Accelerator status:
Warranty alert
Adapter/NVRAM ID
mismatch
Battery pack X
below reference
voltage
Battery X not fully
charged
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Description
Valid data was found in
Not an error or data loss condition. No action needs
posted write memory at
to be taken.
reinitialization. Data will
be flushed to disk.
Catastrophic problem
Replace the array accelerator board.
with array accelerator
board. Refer to other
messages on
Diagnostics screen for
exact meaning of this
message.
EISA nonvolatile RAM has
an ID for a different
controller from the one
physically present in the
slot.
Battery pack on the array
accelerator is below the
required voltage levels.
Battery is not fully
charged.
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Recommended Action
Run the System Configuration Utility.
Allow enough time for batteries to recharge (36
hours). If batteries have not recharged after 36
hours, replace the array accelerator board.
If 75% of the batteries present are fully charged,
the array accelerator is fully operational. If more
than 75% of the batteries are not fully charged,
allow 36 hours to recharge them.