Diagnostics Tools
POST Error Messages
Error Code
*1788-Incorrect Drive
Replaced: Drive X
Drive(s) were
incorrectly replaced:
Drive Y
Select F1 to continue
- drive array will
remain disabled.
Select F2 to reset
configuration - all
data will be lost.
*NOTE : The 1788 error message might also be displayed inadvertently because of a bad
power cable connection to the drive or by noise on the data cable. If this message was
caused by a bad power cable connection, but not caused by an incorrect drive
replacement, repair the connection and press F2.
-Or-
If this message was not caused by a bad power cable connection, and no drive
replacement took place, this could indicate noise on the data cable. Check cable for proper
routing.
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Audible
Beeps
L=Long
S=Short
None
Drives are not installed in
their original positions, so
the drives have been
disabled. See note below.
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Probable Source of
Problem
Reinstall the drives
correctly as indicated.
Press F1 to restart the
computer with the
drive array disabled.
-Or-
Press F2 to use the
drives as configured
and lose all the data
on them.