Diagnostics Tools
POST Error Messages
Error Code
177-Configuration
Not Complete
178-Processor
Configuration Invalid
179-System Revision
Mismatch
201-Memory Error
203-Memory Address
Error
205-Cache Memory
Error
205-Option Cache
Memory Error
206-Cache Controller
Error
207-Invalid Memory
Configuration - Check
DIMM [SIMM]
Installation
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Audible
Beeps
L=Long
S=Short
None
Incomplete System
Configuration.
None
Processor type or step
does not match
configuration memory.
None
A board was installed that
has a different revision
date.
None
RAM failure
None
RAM failure
None
Cache memory error
None
Option cache memory
error
None
Cache controller failure
None
Memory module installed
incorrectly
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Probable Source of
Problem
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run Diagnostics.
Run Diagnostics.
Replace the processor
board in the slot
indicated.
Replace the option
cache board.
Run Diagnostics.
Verify placement of
memory modules.
Action