DAAD Diagnostic Messages
Message
Loose cable
detected - logical
drives may be
marked FAILED until
corrected
Mirror data
miscompare
Mirrored memory
location errors
No configuration for
Accelerator Board
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Description
Controller unable to
communicate with one or
more physical drives,
probably because of a
cabling problem. Logical
drives may be in a
FAILED state until the
condition is corrected,
preventing access to
data on the controller.
Data was found at
reinitialization in the
posted write memory,
however, the mirror data
compare test failed
resulting in data being
marked as invalid. Data
loss is possible.
Soft errors occurred
when attempting to read
the same data from both
sides of the mirrored
memory. Data loss will
occur.
The array accelerator
board has not been
configured.
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Recommended Action
Check all controller and drive cable connections.
Replace the array accelerator board.
Replace the array accelerator board.
If the array accelerator board is present, run the
System Configuration Utility to configure the
board, if desired.
Compaq ProSignia 200 Server Reference Guide