Compaq ProSignia 200 Manual page 164

Hide thumbs Also See for ProSignia 200:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DAAD Diagnostic Messages
Message
Drive (bay) X is
undergoing drive
recovery
Drive (bay) X was
inadvertently
replaced
SCSI port X, drive ID
Y firmware needs
upgrading
Set configuration
command issued
Soft Firmware
Upgrade required
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Description
This drive is being rebuilt
from the corresponding
mirror or parity data.
The physical drive was
incorrectly replaced after
another drive failed.
Drive's firmware may
cause problems and
should be upgraded.
The configuration of the
array controller has been
updated. The array
accelerator board may
remain disabled until it is
reinitialized.
DAAD has determined
that your controller is
running firmware that
has been soft upgraded
by the Compaq Upgrade
Utility. However, the
firmware running is not
present on all drives.
This could be caused by
the addition of new
drives in the system.
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Recommended Action
Normal operations should occur.
Replace the drive that was incorrectly replaced
and replace the original drive that failed. Do not
run the System Configuration Utility and try to
reconfigure - data will be lost.
Run Options ROMPaq to upgrade the drive's
firmware to a later revision.
Run the System Configuration Utility to reinitialize
the array accelerator board.
Run the Compaq Upgrade Utility to place the
latest firmware on all drives.
Compaq ProSignia 200 Server Reference Guide
8-51
continued