8-8
Diagnostics Tools
POST Error Messages
Error Code
1151-Com Port 1
Address Assignment
Conflict
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
1600-Server
Manager/R Failure
1610-Temperature
Violation Detected.
Waiting for system to
cool.
1611-Fan Failure
Detected
1612-Primary Power
Supply Failure
1613-Low System
Battery
1701-SCSI Controller
failure
Writer: Compaq Computer Corporation Project: Diagnostics Tools Comments:
continued
Audible
Beeps
L=Long
S=Short
2S
Both external and internal
serial ports are assigned
to COM1.
2S
Both external and internal
serial ports are assigned
to COM2, COM3, or
COM4.
None
Server Manager/R board
failure. Error code
displays after error
message.
2S
Ambient system
temperature too hot.
2S
Required fan not installed
or spinning.
2S
Primary power supply has
failed.
None
Real time clock system
battery is running low on
power.
None
A test on the Fast SCSI-2
Controller failed
File Name: J-ch8.doc Last Saved On: 4/14/97 12:05 PM
Probable Source of
Problem
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run Diagnostics.
Replace failed
assembly or contact
your service provider
Check fan in system
environment.
Check fans.
Replace power supply
as soon as possible.
Run Diagnostics.
Contact your service
provider.
Contact your service
provider.
Action
continued

Advertisement