4 System Design
4-2
Wiring
This section provides information on the power supply, main circuit, terminal blocks and other parts of the G5-series Servo Drives.
4-2-1
Peripheral Equipment Connection Examples
R88D-KN01L-ECT-L/-KN02L-ECT-L/-KN04L-ECT-L
R88D-KN01H-ECT-L/-KN02H-ECT-L/-KN04H-ECT-L/-KN08H-ECT-L/
-KN10H-ECT-L/-KN15H-ECT-L (Single-phase Input)
R
T
1
2
E NF
3
4
Ground to
100 Ω or less
1MC
Reactor
Regeneration
(*4)
resistor (*5)
X
24 VDC
External sensor, etc.
X
User-side
control
device
4 - 14
Single-phase 100 to 120 VAC, 50/60Hz: R88D-KN
Single-phase 200 to 240 VAC, 50/60Hz: R88D-KN
NFB
Noise filter (*1)
Main circuit
power supply
X
OFF
ON
1MC
X
G5-series AC Servo Drive
CNA
L1C
CNB
L2C
U
V
W
CNA
L1
L3
CNB
CN4
B1
B3
B2
CN1
3
/ALM
4
ALMCOM
General-purpose
inputs 1 to 8
CN1
OUTM1
1
(BKIR)
OUTM1
2
ECAT
COM
IN
OUT
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
L-ECT-L
H-ECT-L
Main circuit contactor (*1)
1MC
Surge suppressor (*1)
PL
Servo error display
Power cables (*2)
Ground to
100 Ω or less
External encoder
cables
*1. A recommended product is listed in 4-3, Wiring Confirming
to EMC Directives.
*2. Do not use shielded cables for power cables.
*3. Recommended relay: MY relay by OMRON (24 VDC 2A)
Select one that matches the ratings of the brake etc. to be used.
*4. Models with a built-in Regeneration Resistor
24 VDC
XB
(KN04L-ECT-L, KN08H-ECT-L, KN10H-ECT-L, and
KN15H-ECT-L) have B2 and B3 shorted. When the
(*3)
amount of regeneration is large, remove the connection
between B2 and B3 and connect the Regeneration
Resistor between B1 and B2.
*5 There is no Internal Regeneration Resistor for KN01L-ECT-L,
KN02L-ECT-L, and KN01H- ECT-L to KN04H-ECT-L. When
the amount of regeneration is large, connect the necessary
Regeneration Resistor between B1 and B2.
Motor
coil unit
External encoder
LM