Omron R88L-EC Series User Manual page 592

Ethercat communications linear motor type
Table of Contents

Advertisement

Appendices
Event name
Interface Output Function Number Error 2
Description
There is an undefined number specification in the output signal (OUTM2) function allocation.
EtherCAT Master Function Module
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
Cause and
There is an undefined number
correction
specification in the output signal
(OUTM2) function allocation.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F533 is given as the AlarmCode (4001 hex).
Remarks
A - 142
Source
details
Minor fault
Recovery
Continues.
Operation
Variable
None
Allocate the functions to the
connector pins using only the
numbers that are defined.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event code
Slave
Error reset
(after cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP NET ERR
Data type
Correction
384A 0000 hex
When
establishing
communications
after turning ON
Detection
power to the
timing
slave or when
transferring
EtherCAT
Configuration
Setup
System
Log category
EtherNet/IP LINK/ACT
Name
Prevention
Allocate the functions to the
connector pins using only the
numbers that are defined.

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn ect-l series

Table of Contents